Charger : in several UPS systems as a result of nature of these design another battery charger is used, this is more common on sub 60kVA UPS systems and is quite common on small sub 3kVA devices.
Battery : this is the power storage section and is kept charged eith...
Rectifier : this part of the UPS charging current for the battery and also the supply requirements for the inverter and can converts the incoming alternating current (ac) supply to direct current (dc).
Charger : in numerous UPS systems because of the nature of the design a separate battery charger is employed, this is very common on small sub 3kVA models and is more common on sub 60kVA UPS systems.
Battery : here is the power storage area and is kept charged both by the rectifier or even a separate charger. As AH (ampere hour), which will be the number of amperes of current that the battery can provide for an hour, Its storage capacity is usually displayed. There will be an amount of limiting factors depending upon the application, generally if the design calls for a short autonomy (length of time the battery will support its weight for), the batteries may be released to a degree, in the case of emergency lighting where there is a necessity for a autonomy the battery won't be permitted to discharge so far. These conditions help allow the maximum design life of the battery to be achieved.
Inverter : this portion of the Uninterruptible power supply has an ac output to the load that is in phase with the insight mains supply. Due to the amount of conversions (ac to dc to ac) and the filtering involved it could be termed as a 'clean source.'
Static Switch : this circuit is often as easy as an exchange or maybe more commonly using thyristors, its purpose is to switch the load between the energy mains supply and the inverter. In order that any switching between your two will soon be nearly seamless as has been earlier mentioned the production of the inverter is in phase with the power mains source. This arrangement ensures that if the inverter experiences an overload situation, due to its fast over-current recognition circuits it'll transfer the load to the more resistant mains supply. A typical example would be when a host tray is switched on, the inrush current, based upon the size of your uninterruptible power supplies, may cause the transfer to the utility mains supply, and once switched on the load may transfer back to the inverter providing the inverter has sufficient ability to support the load. Also a fault on the inverter can cause the load to be moved, again nearly seamlessly; it would be unusual for just about any loss in load to occur during these conditions.
Maintenance Bypass : more on average found in UPS systems with a capacity of 6kVA or greater. The load is allowed by this arrangement to be transferred under controlled conditions to the UPS and the utility mains to be power down without damage. Generally completed for program UPS preservation or UPS fix.
External Maintenance Bypass : the installing an maintenance bypass can allow the UPS to be removed/replaced without interruption to the load, also, if the actual maintenance bypass is given from another source it can allow load screening in the case of a major UPS restoration and/or checking of the autonomy under simulated load circumstances while the site load has been supported by the external maintenance bypass circuit. This could be used when letting the UPS System to be bypassed onto standby diesel generator power. Instead, when batteries are removed and replaced, it could only be done by putting the uniterruptible power into outer bypass. read more